PAGE
Selecting A Pressure Gauge .......................... 4
BIMETAL THERMOMETERS
Introduction ..................................................45
Adjustable Angle AFCF ..................................46
3˝ Dial Size – Rigid Forms 3A, 3S ................47
5˝ Dial Size – Rigid Forms 5A, 5S .................48
3˝ Dial Size – Heavy Duty H3A, H3S ..............49
Pocket Bimetal IR, 2R, 2T .............................50
GLASS THERMOMETERS
Adjustable Glass Thermometers
A735, A935 ...................................................55
Adjustable Air Duct Thermometers
D735, D790 ................................................... 56
Adjust Angle Digital Thermometers
AD35, AD60 ..................................................57
Dimensions, Thermowells ............................ 58
Marine Thermometers S520, S540 ...............59
Economy Glass Thermometers E520L ..........60
GAS ACTUATED THERMOMETERS
Case Styles/Dimensions .......................... 62-63
Selection Terms ............................................64
How to Order .......................................... 65-66
Thermowells .................................................67
Temperature Conversion Table ......................68
4
Pressure Gauge Selection
Considerations in Selecting
a Pressure Gauge
4
RANGE
The maximum operating pressure should not
exceed 75% of the full-scale range. The normal
operating range should be in the middle half of
the range (between 25% and 75% of the full-
scale range); whenever possible.
DIAL SIZE
Select a dial size that allows you to comfortably
read the dial from the normal distance when
installed.
PRESSURE SYSTEM MATERIAL
The media to which the gauge will be subjected
is critical to the selection of the proper material
for the Bourdon tube, bellows, and socket.
Weksler models are offered with:
Phosphor bronze Bourdon tube (or bellows)
with brass sockets.
316 stainless steel Bourdon tube (or
bellows) with 316 stainless steel sockets.
316 stainless steel Bourdon tube with alloy
steel sockets.
Monel Bourdon tubes with Monel sockets.
For applications where the above materials
may not be suitable, a diaphragm seal will
be necessary to protect the pressure gauge
system.
ACCURACY
Select a gauge with the desired accuracy as
follows:
1
/4% test gauges only (not for in-line
service)
1
/2% Weksler Royal gauges (4
1
/2˝ dial
size and larger) and Weksler digital
gauges (2
1
/2˝ case size)
1% Weksler Regal gauges, 100 MM
Gauge, EA14 gauge
2-1-2% Weksler duplex, differential and low
pressure gauges
3-2-3% Weksler BY12, BY42, UA15, UA20,
UA25, UA35 series utility gauges
MOVEMENT
Select either a gauge with 300 series stainless
steel movement for long wear or a gauge with
bronze or brass movement for applications
where vibration and pulsation are not present.
CASE
A wide variety of case styles and materials
are offered. Determine how the gauge is to
be mounted: direct, surface (wall) or flush (in
panel). Determine the desired case materials:
polyproylene (or phenol); aluminum (black
enameled) or stainless steel (300 series).
WARNING: Misuse, Including Excessive
Pressure, Vibration, Pulsation, Tempera-
ture And Corrosion May Cause Failure
That Can Result in Damage Or Injury.
We suggest that users of Pressure
Gauges refer to American National
Standard ASME B40.1 entitled “Gauges,
Pressure And Vacuum Indicating Dial
Type – Elastic Element” for guidance in
Gauge selection. This document may
be obtained from American Society of
Mechanical Engineers (ASME) United
Engineering Center, 345 East 47th Street,
New York, N.Y. 10017.
Determine case type:
Safety
(solid front with blow-out back)
Standard
(open front with rubber blow-out disc at rear)
Note – All safety case styles are designated
by a number. Standard case styles are
designated by a letter.
WINDOW
A glass face is standard in most gauges. If
breakage is a concern, a plastic or shatterproof
glass face is optional at extra cost on most
Weksler Royal and Regal gauges. (Glycerin
filled and sanitary gauges have plastic face as
standard).
POINTER
All Weksler gauges (except utility types) have
adjustable pointers. This permits pointer repo-
sitioning during calibration check or allows
maximum precision at a specific point.
TEMPERATURE
The ambient temperature to which the gauge
will be subjected should not exceed 150°F. If
higher temperatures are encountered the gauge
must be isolated from the source of heat. The
temperature of the media to which the gauge
is subjected to is also critical. Gauges with
phosphor bronze Bourdon tubes should not be
subjected to process temperatures in excess
of 150°F. Gauges with metal cases and either
316 stainless steel or monel bourdons can
withstand higher process temperatures, but
as temperature exceeds 150°F hardening of
the gasketing and discoloration of the dial may
occur. In addition, accuracy will be affected
by approximately 1.5% per 100°F. Both 316
stainless steel and monel gauges in metal cases
will withstand 750°F for short periods of time
without rupture, but other parts of the gauge
will be destroyed and calibration will be lost.
VIBRATION
If present, a glycerin filled gauge is
recommended.
PULSATION
If present, a pressure snubber or throttle screw
is recommended.
5
BIMETAL
THERMOMETERS
Introduction .....................................................................7
Adjustable Angle ..............................................................8
3˝ Dial Size – Rigid Forms ................................................9
5˝ Dial Size – Rigid Forms ..............................................10
3˝ Dial Size – Heavy Duty ...............................................11
Pocket Bimetal ...............................................................12
Sanitary Wells, Conversion Kit, Duct Flange ..................13
6
7
RANGE
The maximum operating pressure should not
exceed 75% of the full-scale range. The normal
operating range should be in the middle half of
the range (between 25% and 75% of the full-
scale range); whenever possible.
DIAL SIZE
Select a dial size that allows you to comfortably
read the dial from the normal distance when
installed.
ACCURACY
All Weksler BiMetal Thermometers have an
accuracy of ± 1% of the full-scale range. For
accurate readings stem must be immersed at
least 2 inches in liquids and 4 inches in gases.
UNDER/OVER RANGE PROTECTION
Temporary exposure to temperatures under or
over 50% of the full-scale range will not impair
accuracy (up to 500°F or 260°C maximum).
CASE ASSEMBLY
The case, bezel, stem and fittings are stainless
steel (300 series). The head assembly is sealed
to exclude dirt, dust and moisture on 3˝ and 5˝
dial sizes, all joints are welded.
DIALS
Dials are white with clear black graduations
and numerals and are easy to read.
FACE
A gasketed glass window is standard on 3˝ and
5˝ dial sizes. Where breakage is a concern, a
plastic or shatterproof glass window is optional
at extra cost. On 1˝ and 2˝ dial sizes a plastic
window is standard (no options available).
Plastic windows are not suitable where head
temperature exceeds 150°F (65°C).
EXTERNAL ADJUSTMENT
An external adjustment at the rear of the 3˝ and
5˝ case permits adjustment at a specific point
or pointer repositioning during calibration
check.
VIBRATION AND SHOCK
If present, use of either a heavy duty bimetal or
a remote mounted gas actuated thermometer
is recommended.
HIGH PRESSURE OR CORROSIVE APPLICATIONS
In these applications, use of a separable ther-
mowell is recommended. In addition to pro-
tecting the thermometer, thermowells facilitate
removal of the thermometer without having to
shut down the system.
8
Adjustable Angle Type
3˝ and 5˝ Dial SIze
All Stainless Steel Construction
• External Recalibration Adjustment
• White dial with black markings
• Accurate to ±1% of Scale Range
• Gasketed Glass Face
ADJUST-ANGLE
TYPE AF
3˝ AND 5˝ DIAL SIZE CATALOG NUMBERS
STEM FIXED THREAD UNION CONNECTED
LENGTH 3˝ 5˝
2
1
2˝ CF02 AF02 CU02 AU02
CF04 AF04 CU04 AU04
CF06 AF06 CU06 AU06
CF09 AF09 CU09 AU09
12˝ CF12 AF12 CU12 AU12
15˝ CF15 AF15 CU15 AU15
18˝ CF18 AF18 CU18 AU18
24˝ CF24 AF24 CU24 AU24
NOTE: Union connected types must be used with thermowells, longer length available on special order.
Case is sealed to exclude dirt, dust and moisture
3˝ and 5˝ dial sizes
Angularly adjustable frame permits
positioning of dial to accommodate viewing
requirements
* Not recommended for continuous service above 800°F (425°C).
For such temperatures see pg. 63.
†Minimum stem length for these ranges 4˝.
DUAL SCALE
Fahrenheit Celsius
CODE (on outside and (on inside)
DE -40/120°F and -40/50°C
DF 40/160°F and -40/70°C
DN 30/130°F and 0/55°C †
DJ 0/200°F and -20/94°C
DL 0/250°F and -20/120°C
DR 50/300°F and 10/150°C
DS 50/400°F and 10/200°C
DT 50/550°F and 10/290°C
DX 100/800°F* and 40/430°C†
DY 200/1,000°F and 100/550C*†
CODE Fahrenheit
FC –80 to 120°F
FE –40 to 120°F
FG 0 to 150°F
FJ 0 to 200°F
FL 0 to 250°F
FM 30 to 240°F
FN 30 to 130°F †
FR 50 to 300°F
FS 50 to 400°F
FT 50 to 550°F
FX 150 to 750°F†
FY 200 to 1000°F*†
Celsius
CD –50 to 50°C
CJ 0 to 100°C
CM –10 to 110°C
CN 0 to 50°C †
CR 0 to 150°C
CS 0 to 200°C
CU 0 to 300°C
CX 50 to 450°C†
CY 100 to 550°C*†
SEPARABLE THERMOWELLS AVAILABLE
SEE PAGES 59 - 63
STANDARD RANGES
A F 0 6 4 4 F M X
1. Basic 4-digit Catalog No. From Table Above
——————————————
2. Stem Diameter: “4” = .250˝O.D. (Standard); “5” = .375˝O.D. (Extra Cost)
—————————
3. Thread Size: “4” =
1
/2 NPT Male (AF Series); “U” =
1
/2 NPT Male Swivel Nut (AU Series)
——————
4. 2 Digit Range Code from Range Tables Above
————————————————————————————
5. Option(s): “X” = None Required; “9” = Option(s) Required (Extra Cost)
————————————————————
HOW TO ORDER
If option(s) are required specify: Plastic Face, Shatterproof Glass Face, Paper Tag, Stainless Steel Tag
STANDARD RANGES
OPTIONAL FEATURES
CODE Description
EL Liquid Filling for Catalog No’s AF, 3A, 5A only
PD Plastic Window
SG Shatter Proof Glass
NN Paper Tag
NH Stainless Steel Tag
DM Dial Markings
C4 Calibration Certificate
9
90° BACK
ANGLE FORM
TYPE 3A
MOUNTING DIMENSIONS
TYPES 3S, 3L & 3R
STRAIGHT FORM
TYPE 3S
5
16
(8)
19
32
(15)
3
5
32
(80)
See stem length options in chart to left.
MOUNTING DIMENSIONS
TYPES 3A
Longer stem lengths available on special order.
All Stainless Steel Construction
• External Recalibration Adjustment
• White dial with black markings
• Accurate to ±1% of Scale Range
STANDARD FEATURES
• Gasketed Glass Face
Case is sealed to exclude dirt, dust and moisture
• 3˝ dial size
CATALOG NUMBERS*
STEM 90° BACK STRAIGHT
LENGTH ANGLE FORM FORM
2
1
2˝ 3A02 3S02
3A04 3S04
3A06 3S06
3A09 3S09
12˝ 3A12 3S12
15˝ 3A15 3S15
18˝ 3A18 3S18
24˝ 3A24 3S24
* Not recommended for continuous service above 800°F (425°C).
For such temperatures see pg. 63.
†Minimum stem length for these ranges 4˝.
DUAL SCALE
Fahrenheit Celsius
CODE (on outside and (on inside)
DE –40/120°F and –40/50°C
DF 40/160°F and –40/70°C
DN 30/130°F and 0/55°C †
DJ 0/200°F and –20/94°C
DL 0/250°F and –20/120°C
DR 50/300°F and 10/150°C
DS 50/400°F and 10/200°C
DT 50/550°F and 10/290°C
DX 100/800°F* and 40/430°C†
DY 200/1,000°F and 100/550C*†
CODE Fahrenheit
FC –80 to 120°F
FE –40 to 120°F
FG 0 to 150°F
FJ 0 to 200°F
FL 0 to 250°F
FM 30 to 240°F
FN 30 to 130°F †
FR 50 to 300°F
FS 50 to 400°F
FT 50 to 550°F
FX 150 to 750°F†
FY 200 to 1000°F*†
Celsius
CD –50 to 50°C
CJ 0 to 100°C
CM –10 to 110°C
CN 0 to 50°C †
CR 0 to 150°C
CS 0 to 200°C
CU 0 to 300°C
CX 50 to 450°C†
CY 100 to 550°C*†
3 S 0 4 4 4 D R X
1. Basic 4-digit Catalog No. From Table Above
——————————————
2. Stem Diameter: “4” = .250˝O.D. (Standard); “5” = .375˝ O.D. (Extra Cost)
————————
3. Thread Size: “4” =
1
/2 NPT Male; 2 =
1
/4 NPT Male Back Angle Rear Only (Extra Cost)
———————
4. 2 Digit Range Code from Range Tables Above
————————————————————————————
5. Option(s): “X” = Non Required Option(s) Required (Extra Cost) Select code from above table
———————————
HOW TO ORDER
Rigid Forms – 3˝ Dial Size
STANDARD RANGES
OPTIONAL FEATURES
CODE Description
EL Liquid Filling for Catalog No’s AF, 3A, 5A only
PD Plastic Window
SG Shatter Proof Glass
NN Paper Tag
NH Stainless Steel Tag
DM Dial Markings
C4 Calibration Certificate
SEPARABLE THERMOWELLS AVAILABLE
SEE PAGES 59 - 63
10
Rigid Forms – 5˝ Dial Size
Longer stem lengths available on special order
BACK ANGLE
FORM TYPE 5A
STRAIGHT
FORM
TYPE 5S
MOUNTING DIMENSIONS
FOR 5˝ DIAL SIZE
THERMOMETER
TYPES 5S, 5L & 5R
MOUNTING DIMENSIONS
TYPE 5A
All Stainless Steel Construction
• External Recalibration Adjustment
• White dial with black markings
• Accurate to ±1% of Scale Range
• Gasketed Glass Face
Case is sealed to exclude dirt, dust and moisture
• 5˝ dial size
CATALOG NUMBERS*
STEM 90° BACK STRAIGHT
LENGTH ANGLE FORM FORM
2
1
2˝ 5A02 5S02
5A04 5S04
5A06 5S06
5A09 5S09
12˝ 5A12 5S12
15˝ 5A15 5S15
18˝ 5A18 5S18
24˝ 5A24 5S24
* Not recommended for continuous service above 800°F (425°C).
For such temperatures see pg. 63.
†Minimum stem length for these ranges 4˝.
DUAL SCALE
Fahrenheit Celsius
CODE (on outside and (on inside)
DE –40/120°F and –40/50°C
DF 40/160°F and –40/70°C
DN 30/130°F and 0/55°C †
DJ –0/200°F and –20/94°C
DL 0/250°F and –20/120°C
DR 50/300°F and 10/150°C
DS 50/400°F and 10/200°C
DT 50/550°F and 10/290°C
DX 100/800°F* and 40/430°C†
DY 200/1,000°F and 100/550C*†
CODE Fahrenheit
FC –80 to 120°F
FE –40 to 120°F
FG 0 to 150°F
FJ 0 to 200°F
FL 0 to 250°F
FM 30 to 240°F
FN 30 to 130°F †
FR 50 to 300°F
FS 50 to 400°F
FT 50 to 550°F
FX 150 to 750°F†
FY 200 to 1000°F*†
Celsius
CD –50 to 50°C
CJ 0 to 100°C
CM –10 to 110°C
CN 0 to 50°C
CR 0 to 150°C
CS 0 to 200°C
CU 0 to 300°C
CX 50 to 450°C†
CY 100 to 550°C*†
5 A 0 6 4 4 F J X
1. Basic 4-digit Catalog No. From Table Above
——————————————
2. Stem Diameter: “4” = .250˝O.D. (Standard); “5” = .375˝ O.D. (Extra Cost)
————————
3. Thread Size: “4” =
1
/2 NPT Male; 2 =
1
/4 NPT Male, Back Angle Rear Only(Extra Cost)
———————
4. 2 Digit Range Code from Range Tables Above
————————————————————————————
5. Option(s): “X” = Non Required Option(s) Required (Extra Cost) Select code from above table
———————————
HOW TO ORDER
STANDARD FEATURES
STANDARD RANGES
SEPARABLE THERMOWELLS AVAILABLE
SEE PAGES 59 - 63
OPTIONAL FEATURES
CODE Description
EL Liquid Filling for Catalog No’s AF, 3A, 5A only
PD Plastic Window
SG Shatter Proof Glass
NN Paper Tag
NH Stainless Steel Tag
DM Dial Markings
C4 Calibration Certificate
11
Heavy Duty Types –
3˝ Dial Size
• Shock and Vibration Resistant
Stainless Steel Construction
Plastic Crystal
• Dished Anti-Parallax Dial for Easy Reading
External Recalibration Adjustment at Rear
of Case
CATALOG NUMBERS
STEM 90° BACK STRAIGHT
LENGTH ANGLE FORM FORM
2˝ H3A2 H3S2
H3A4 H3S4
H3A6 H3S6
NOTE: A minimum of 2˝ insertion (immersion) is required for accurate
readings and proper response.
CODE Fahrenheit
D –40 to 120°F in 2° divs.*
H 0 to 200°F in 2° divs.
L 20 to 240°F in 2° divs.
P 50 to 300°F in 2° divs.
Q 50 to 400°F in 5° divs.
R 50 to 500°F in 5° divs.
S 50 to 750°F in 10° divs.
CODE Celsius
1 –50 to 50°C in 1° divs.*
2 –10 to 110°C in 1° divs.
5 0 to 150°C in 2° divs.
6 0 to 200°C in 2° divs.
8 0 to 300°C in 5° divs.
THERMOWELLS FOR HEAVY DUTY BIMETAL THERMOMETERS
.385˝ BORE
3/4-28˝ FEMALE THREAD (INTERNAL)
CATALOG NO.
WELL
THERMOMETER LENGTH
STEM LENGTH (OVERALL) 304 SS
2˝ 3
1
4˝ W3G1
5
1
4˝ W5G1
7
1
4˝ W7G1
THREADED TYPE –
3
/4-14 NPT MALE
TYPE H3A
90° BACK ANGLLE
*4˝ MINIMUM STEM LENGTH
(ON STRAIGHT FORM ONLY)
To Order: Specify 4 digit catalog no. from above tables
Accurate to 1% of Scale Range (when tested
without well)
Interchangeable with 5˝ Scale Size “Submarine”
Thermometers Having Same Stem Length
3
4˝-28 UN2A Union Connection Assembly
Must be used with Well (or Bushing)
H 3 S 4 H
1. Basic 4-digit Catalog No.
—————————————————————
2. Range Code
—————————————————————————————————
HOW TO ORDER
TYPE H3S
STRAIGHT FORM
STANDARD FEATURES
12
Pocket Bimetal – 1˝ and 2˝
• 1˝ dial
• 5˝ stem length
• .142˝ stem diameter
• Complete with pocket case and clip
Standard with plastic crystal and recalibration
feature
• 2˝ dial
All Stainless Steel Construction
• Accurate to ±1% of Scale Range
Dual Scale (Both °F and °C) Ranges
CATALOG STANDARD
NUMBER RANGES
1R05A -40 to 160°F in 2° divs.
1R05B 25 to 125°F in 1° divs.
1R05C 0 to 220°F in 2° divs.
1R05D 50 to 550°F in 5° divs.
1R05E -50 to 100°C in 2° divs.
1R05F -10 to 110°C in 2° divs.
1R05G 0 to 150°C in 2° divs.
1R05H 0 to 250°C in 5° divs.
CATALOG DUAL SCALE (BOTH °F AND °C)
NUMBER FAHRENHEIT ON OUTER – CELSIUS ON INNER SCALE TYPE
2R08A –40 to 160°F in 2° divs. and –40 to 70°C in 2° divs.
2R08B 25 to 125°F in 1° divs. and –5 to 50°C in 1° divs.
2R08J 0 to 180°F in 2° divs. and –18 to 83°C in 1° divs.
8˝ Plain Stem
2R08C 0 to 220°F in 1° divs. and –10 to 110°C in 2° divs.
With Recalibration
2R08K 50 to 400°F in 5° divs. and 10 to 106°C in 2° divs.
Feature
2R08D 50 to 550°F in 5° divs. and 10 to 290°C in 5° divs.
2T02A –40 to 160°F in 2° divs. and –40 to 70°C in 2° divs. 2
1
2˝ Stem
2T02C 0 to 220°F in 2° divs. and –10 to 110°C in 2° divs.
1
4 NPT Fixed Thread
2T04A –40 to 160°F in 2° divs. and –40 to 70°C in 2° divs.
4˝ Stem
2T04B 25 to 125°F in 1° divs. and –5 to 50°C in 1° divs.
1
4 NPT Fixed Thread
2T04C 0 to 220°F in 2° divs. and –10 to 110°C in 2° divs.
MODEL 1R05
MODEL 2T02
MODEL 2R08
HOW TO ORDER
Specify 5 digit catalog number from above tables
STANDARD FEATURES
STANDARD FEATURES
MOUNTING CLIP FOR 1˝ and 2˝ PN TPC
13
Standard Threaded Thermowells
58
FOR INDUSTRIAL BIMETAL THERMOMETERS
WITH .250˝ DIAMETER ELEMENTS
.385˝ bore available for use with instruments
with .375˝ diameter elements
All Weksler standard thermowells are bored
from solid bar stock
Brass wells are not recommended for installations involving high pressures and/or temperatures over 400°F.
Brass cap and chain available to keep bore clean when not in use.
.260˝ bore standard. If .385˝ bore is required:
(1) Add the letter K at the end of the catalog no.;
(2) “Q” diameter is changed to 49/64˝ along entire length of insertion (“U” dimension).
For pressure – temperature rating use Table 1 on page 89.
NOTE: 2
1
2˝ STEM THERMOMETERS USE SPECIAL LIMITED SPACE WELLS.
WITHOUT LAGGING EXTENSION
304 316
A U Q BRASS SS SS
4 2
1
2 S3B4 S3G4 S3J4
6 4
1
2
3
4 S3B6 S3G6 S3J6
9 7
1
2
3
4 S3B9 S3G9 S3J9
12 10
1
2
3
4 S3B2 S3G2 S3J2
3
/4 NPT – CATALOG NUMBERS
14
15
GLASS
THERMOMETERS
Adjustable Angle Glass Thermometers ..........................17
Adjustable Angle Air Duct Thermometers ......................18
Adjust Angle Digital Thermometers ................................19
Dimensions, Thermowells ..............................................20
Navy/Marine Thermometer ............................................21
Economy Glass Thermometer ........................................21
16
17
STANDARD FEATURES
Mercury Free.
Molded Valox
®
– V-shaped black case for
ranges up to and including 300°F
Die cast black aluminum V-shaped case for
ranges above 300°F.
Glass front excludes dust and dirt.
White aluminum scale with bold black
graduations and figures.
Mercury Free blue liquid in glass with
magnifying lens for easy readability.
Accuracy is ±1% of full scale.
Easy adjustment permits case and stem to
be rotated 360°.
3
1
2
˝, 6˝, 9˝ & 12˝ stems available.
1
1
4
˝-18˝ NEF swivel nut.
RANGES
MINOR RANGE
FAHRENHEIT GRADS CODE
–40/110F F1
0/120F F2
0/160F F3
30/180F F4
30/240F F5
30/300F F6
50/400F
(1)
5° F7
50/550F
(1)
5° F8
CELSIUS
–20/45C
1° C1
0/50C
1° C2
0/100C
1° C3
0/160C
(1)
2° C4
0/200C
(1)
2° C5
0/300C
(1)
5° C6
DUAL SCALE
–40/110F & –40/43C
2° D1
0/120F & –15/48C
1° D2
0/160F & –15/70C
2° D3
30/180F & 0/82C
2° D4
30/240F & 0/115C
2° D5
30/300F & 0/150C
5° D6
50/400F & 10/200C
(1)
5° D7
50/550F & 10/290C
(1)
5° D8
(1) Must be supplied with optional aluminum case.
Adjust Angle Thermometer,
Mercury Free, Standard
Model A935AF5
Plastic window available for both 7˝ and 9˝scale.
Aluminum case available for low ranges
(300°F and below).
A 9 35 A F5 — AL
1. Product Type:
A = Adjust Angle Thermometer
2. Scale Size: 7 = 7˝ Scale; 9 = 9˝ Scale
3. Stem Length: 35 = 3
1
/2˝; 60 = 6˝; 90 = 9˝; 12 = 12˝
4. Connection Location: A = Adjust Angle
5. Range (see table)
6. Options: AL = Aluminum Case*; PD = Plastic Window
HOW TO ORDER
OPTIONS
Model A935AF5
*Aluminum case is required for ranges over 300°F
18
D 9 60 A F2 — AL
1. Product Type:
D = Air Duct Thermometer
2. Scale Size: 7 = 7˝ Scale; 9 = 9˝ Scale
3. Stem Length: 35 = 3
1
/2˝; 60 = 6˝; 90 = 9˝; 12 = 12˝
4. Connection Location: A = Adjust Angle
5. Range (see table)
6. Options: PD = Plastic Window, AL = Aluminum Case
Mercury Free.
Molded Valox
®
– V-shaped black case
supplied as standard.
Glass front excludes dust and dirt.
White aluminum scale with bold black
graduations and flanges.
Mercury Free blue liquid in glass with
magnifying lens for easy readability.
Accuracy is ± 1% of full scale.
Easy adjustment permits case and stem to
be rotated 360°.
3
1
2
˝, 6˝, 9˝ & 12˝ stems available.
Protective slotted bulb guard,
3
4
˝ diameter
aluminum stem and 3˝ diameter union
flange
RANGES
MINOR RANGE
FAHRENHEIT GRADS CODE
–40/110F 2° F1
0/120F F2
0/160F F3
30/180F F4
30/240F F5
CELSIUS
–20/45C
1° C1
0/50C
1° C2
0/100C
1° C3
DUAL SCALE
–40/110F & –40/43C
2° D1
0/120F & –15/48C
1° D2
0/160F & –15/70C
2° D3
30/180F & 0/82C
2° D4
30/240F & 0/115C
2° D5
Adjust Angle Air Duct Thermometer,
Model D960AF2
HOW TO ORDER
Plastic window available for both 7˝ and 9˝ scale.
Lagging extension.
Aluminum case.
STANDARD FEATURES
OPTIONS
Model D960AF2
19
Bulb Chamber
2.4
4.5
2.5
3.5
or
6.0
Swivel Nut
Angle Adj. Screw
F°/C°
Switch
Solar
Panels
1.14
.75 Dia.
Taper
1
1
4-18 THD
Case Locknut
.435 Dia.
LIGHT-POWERED ADJUSTABLE ANGLE DIGITAL
THERMOMETER
The Weksler
light-powered
industrial
thermometer offers an environmentally
friendly alternative to mercury-filled industrial
thermometers. The light-powered industrial
thermometer can help reduce inventory
requirements with its switchable °F and °C
feature, which offers a wide variety of ranges
in a single unit (–40/300°F and –40°/150°C).
The high impact ABS case can be adjusted for
viewing from any angle. Stem lengths of 3
1
2˝
and 6˝ are available and are interchangeable
with standard glass column industrial
thermometers. The light - powered industrial
thermometer features a
1
2˝ LCD digital display.
SPECIFICATIONS
Switchable Range: –40/300°F - –40/150°C
Accuracy: 1% of reading or 1° whichever is greater
Display:
1
2
˝ LCD digits
Resolution:
1
10° between –19.9/199.9°F or 28/93°C
Update Rate: 10 seconds
Recalibration: Internal potentiometer
Sensor: Glass passivator thermistor
Lux Rating: 10 Lux
Ambient Oper. Temp. –30°F - 140°F
Ambient Temp. Error: Zero
Humidity Rating: 100%
PHYSICAL CHARACTERISTICS
Case:
High-impact ABS
Stem Assemblies, Industrial Glass:
Full conformance with Fed. Spec. GGT-321D
Stem Lengths:
3
1
2˝ and 6˝
Standard Connection:
1
1
4˝-18 NEF Swivel Nut
Weight: 10 oz.
ACCESSORIES
Thermowells For Adjustable
Angle Thermometers:
See page 5
DIMENSIONS
Adjust Angle Digital Thermometer
AD 35 A FC
1. Product Type:
AD = Adjust Angle Digital Thermometer
2. Stem Length: 35 = 3
1
/2˝; 60 = 6˝
4. Connection Location: A = Adjust Angle
5. Range: FC = Switchable Range –40/300°F or –40/150°C
HOW TO ORDER
Model AD35AFC
20
THERMOWELLS FOR ADJUST ANGLE THERMOMETERS
THERMOMETER “T” “U”
3
4 NPT
STEM LENGTH DIM. DIM. BRASS
3
1
2˝ 1 1
1
2˝ G1E3D2B
2
1
2˝ 2
1
2˝ G1M3D2E
2
1
2˝ 5
1
2˝ G1S3D2E
12˝ 2
1
2˝ 8
1
2˝ G1T3D2E
THERMOMETER “U”
3
4 NPT
STEM LENGTH DIM. BRASS
3
1
2˝ 2
1
2˝ G1E3D2
G1M3D2
G1S3D2
12˝ 11˝ G1T3D2
3
4˝
5
8˝
3
4˝ NPT Standard
U
1
1
4˝ –
18 NEF
Thread
T
3
4˝ NPT Standard
1
1
4˝ –
18 NEF
Thread
5
8˝
U
3
4˝
Adjust Angle and Air Duct
Thermometer
General Dimensions
NPT
SCALE
SIZE
1.81
2.25
1.00
U
2.33
1.0
X
2.53
S
LAGGING
EXTENSION
Air Duct Stem
S
.75 DIA
2.38
NO EXTENSION
1.56
1.33 DIA
2 HOLES
.25 DIA ON 2.31
B.C.
3.0
.63 DIA
21
Molded Valox
®
– V-shaped gray case.
Red reading spirit filled tube with
magnifying lens for easy readability.
40/260F and 5/125C is standard range
(2°F divisions and 1°C divisions)
White aluminum scale with bold black
graduations and figures.
2˝ stem supplied as standard.
Supplied standard with removable
1
2
NPT brass well, 2˝ length
(1.375˝ insertion).
PART NUMBERS
CONNECTION
LOCATION
2˝ STEM
Lower E520L
Back E520R
S520L
S520R
STANDARD FEATURES
E520L
E520R
CLASS a WELL
3
4˝ - 14 NPT
CLASS c WELL
1
2 &
3
4˝ - 14 NPT
Economy Thermometer
Marine Thermometer &
Economy Thermometer
RANGES
MINOR RANGE
DUAL SCALE GRADS CODE
–40/110F & –40/43C
2°/2° D1
20/180F & –5/80C
2°/2° DØ
30/240F & 0/115C
2°/2° D5
50/400F & 10/200C
5°/2° D7
PART NUMBERS*
STEM LENGTH
CONNECTION
LOCATION 2˝
Lower S520L
Back S520R
* Include range code (above) at end of above # to
complete the part number.
WELL STEM LENGTH OF OVERALL LENGTH
CATALOG
#
CLASS THERMOMETER OF WELL
BRASS 304SS
a 2 inch 3
1
4˝ N/A W3G1
c 2 inch 3
1
4˝ W3B3 N/A
THERMOWELL DIMENSIONS –
3
4-28˝ Female Thread (Internal)
Navy/Marine Thermometer
Molded Valox
®
– V-shaped gray case.
White aluminum scale with bold black
graduations and flanges.
2˝ stem.
3
1
4
˝ overall length thermowell (optional) to
be used with 2˝ stem.
Red reading with magnifying lens for easy
readability.
STANDARD FEATURES
22
23
GAS ACTUATED
THERMOMETERS
Case Styles/Dimensions ........................................... 24-25
Selection Terms .............................................................26
How to Order ........................................................... 27-28
Thermowells ..................................................................29
Temperature Conversion Table .......................................30
24
Gas Actuated Thermometers –
Case Styles/Dimensions
STYLE DIAL SIZE MATERIAL
P 4
1
2˝ Polypropylene
Snap-in glass retaining ring.
Standard for 4
1
/2˝ remote.
SURFACE (WALL) OR DIRECT MOUNT TYPES
SURFACE (WALL) MOUNT TYPES
STYLE DIAL SIZE MATERIAL
Aluminum
A 4
1
2˝
Black Textured
Enamel Finish
Molded plastic hinged front ring
allows easy access to dial and
pointer.
Extra cost option.
NOTE: Only available with rear (back) connection.
HINGED FRONT TYPE FOR FLUSH MOUNTING
STYLE DIAL SIZE MATERIAL
Aluminum
W 4
1
2˝ Black Textured
Enamel Finish
Style “A” has bayonet type glass
retaining ring.
Extra cost option.
GAUGE SIZE
A B C D E F G H
INCH 5.83 2.56 5.08 2.62 1.00 .20 .24 5.39
4
1
2
X-PANEL HOLE CUT-OUT DIAMETER
SURFACE (WALL) OR DIRECT MOUNT TYPES
SURFACE (WALL) MOUNT TYPES
SURFACE (WALL) MOUNT TYPES
SURFACE (WALL) MOUNT TYPES
HINGED FRONT TYPE FOR FLUSH MOUNTING
GAUGE SIZE
A B C D E F G H
INCH 5.81 2.69 5.00 2.50 1.12 .20 .22 5.38
4
1
2
GAUGE SIZE
A B F G H J
INCH 6.31 1.63 1.35 .19 5.38 4.88
4
1
2
25
Gas Actuated Thermometers –
Case Styles/Dimensions
BAYONET TYPE GLASS
RETAINING RING
4
1
2˝ dial size remote mount
thermometers.
Extra cost option.
STYLE DIAL SIZE(S) MATERIAL
X 4
1
2˝
Stainless Steel
SURFACE (WALL) MOUNT TYPES
SURFACE (WALL) MOUNT TYPES
X-PANEL HOLE CUT-OUT DIAMETER
BAYONET TYPE GLASS
RETAINING RING
Standard on all stainless steel
adjust angle.
STYLE DIAL SIZE(S) MATERIAL
Y 4
1
2˝
Stainless Steel
DIRECT MOUNT TYPES (Flangeless Case)
DIRECT MOUNT TYPES (Flangeless Case)
Front flanged case for semi-flush
mounting.
Bayonet type glass retaining ring.
Extra cost option.
NOTE: Only available with rear (back) connection.
STYLE DIAL SIZE(S) MATERIAL
V 4
1
2˝
Stainless Steel
HINGED FRONT TYPE FOR FLUSH MOUNTING
HINGED FRONT TYPE FOR FLUSH MOUNTING
GAUGE SIZE
A B C G H
4
1
/2 INCH 5.90 2.10 5.05 .22 5.38
GAUGE SIZE
A B C D G H
4
1
/2 INCH 5.90 .94 5.05 1.04 .22 5.55
GAUGE SIZE
A B E F
4
1
/2 INCH 5.04 2.00 1.75 6.81
26
Gas Actuated Thermometers –
Selection Terms
RANGE
The maximum operating temperature should
not exceed 75% of the full-scale range. The
normal operating range should be in the mid-
dle half of the range (between 25% and 75% of
the full-scale range); whenever possible.
ACCURACY
All Weksler gas actuated dial thermometers
have an accuracy of ± 1% of the full-scale
range. For accurate readings the entire sensi-
tive portion of the bulb must be fully immersed
into the medium being measured.
CASE
A wide variety of case styles and materials are
offered. Determine how the thermometer is to
be mounted: direct, surface (wall) or flush (in
panel). Determine the desired case material:
polypropylene, aluminum (black enameled) or
stainless steel (300 series).
FACE
A gasketed glass window is standard. Where
breakage is a concern, a plastic or shatterproof
glass window is optional at extra cost. Plastic
windows are not suitable where head tempera-
ture exceeds 150°F (65°C).
POINTER
All Weksler gas actuated thermometers have
adjustable pointers. This permits pointer repo-
sitioning during calibration check or allows
maximum precision at a selected point within
the scale range.
MOUNTING
Weksler gas actuated thermometers are avail-
able in remote mounted types (with capillary
tubing between case and sensing bulb) and
direct mounted types (sensing bulb is attached
directly to case). Remote mounted types allow
the temperature to be read at a location remote
from the actual temperature source. Remote
mounting is also desirable to isolate the head
(case, scale, pointer and internal parts) from
the damaging effects of shock, vibration or
excessive heat that may be present at the tem-
perature source. Direct mounted thermometers
are available in “adjust angle” types which
allow the head of the thermometer to be posi-
tioned for the most desirable viewing angle.
Direct mounted units are installed directly on
pipes, tanks or other vessels.
BULB TYPES
Weksler gas actuated thermometers are avail-
able with various styles of plain bulbs or union
connection bulbs. The bulb is the sensing ele-
ment at the tip of the thermometer that reacts
to temperature changes. The entire thermome-
ter including the bulb, head assembly and cap-
illary tubing (on remote types) is filled with an
inert nitrogen gas offering fast response and
linear dial graduations. Plain bulbs are those
without threaded fittings for sensing air tem-
perature or liquid temperatures in open tanks,
vats, sinks, etc. Union connected bulbs have
threaded swivel nuts that hold the bulb into a
bulb fitting such as a thermowell, bushing or
flange.
HIGH PRESSURE OR CORROSIVE
APPLICATIONS
In these applications, use of a separable ther-
mowell is recommended. In addition to pro-
tecting the thermometer, thermowells facilitate
removal of the thermometer without having to
shut down the system.
27
Gas Actuated Thermometers –
How To Order
BASE DIAL TYPE
CATALOG NO. SIZE
413B 4
1
2˝ REMOTE MOUNTED
453B 4
1
2˝
ALL STAINLESS STEEL
ADJUSTABLE ANGLE
TABLE 1
REMOTE AND DIRECT MOUNTED TYPES
TABLE 2 – BULB TYPE AND SIZE
PLAIN BULB FOR AIR TEMPERATURE
CODE
A
C*
3
J
13˝ Long
.375 Diameter
PLAIN BULB FOR LIQUIDS IN OPENTANKS, VATS, SINKS, ETC.
6˝ Long
.50˝ Diameter
SLIDING UNION CONNECTION WITH 12˝ BENDABLE EXTENSION
FOR REMOTE MOUNT TYPES
Union Connection (fixed length)
Wells, bushings or flanges required
for installation
3
8˝ O.D. –
1
2˝-14 NPSM Swivel Nut
WALL MOUNTED TYPES
CODE CASE TYPE
P
Molded Polypropylene, Turret Type standard
A Aluminum, Rear Flange
Black Aluminum Bayonet Ring
Extra cost option
X Stainless Steel, Rear Flange
Stainless Steel Bayonet Ring
Extra cost option
FLUSH PANEL MOUNTED STYLES
V Stainless Steel Case and Bayonet Ring
Front Flange – Semi-Flush Mounting
Extra cost option
W Aluminum Case
Hinged Front Plastic Bezel
Extra cost option
TABLE 3 – CASE STYLES
CODE CASE TYPE
Y Stainless Steel, Flangeless
Stainless Steel Bayonet Ring
Standard on base catalog No. 453B
DIRECT MOUNTED TYPES
CODE
N
3˝ x .375˝ Diameter Bulb,
1
/2 NPT Swivel Nut
SLIDING UNION CONNECTION WITH 12˝ BENDABLE EXTENSION
3˝ x .625˝ Diameter Bulb, 1˝-20 NEF-2B Swivel Nut
STEM FITS
CODE LENGTH WELL*
4 4
1
4˝ O.A.
6 6
1
2˝ O.A.
9 9
1
4˝ O.A.
2 12˝ 12
1
4˝ O.A.
*Uses “K” Series Thermowells (See page 7)
3
1
2˝ x .625˝ Diameter Bulb, w/1˝-20 NEF-2B Swivel Nut
18˝ Bendable
8
FOR DIRECT MOUNT TYPES
* Only available with standard spring armor. Cannot exceed 40 ft.
N/A with interlock armor.
28
Gas Actuated Thermometers –
How To Order
4 1 3 B 3 P L S 05 FF ( )
1. Specify 4-digit Base Catalog No. from Table 1 —————————————
2. Add Bulb Digit from Table 2 ——————————————————————————
3. Add Case Style Digit from Table 3 ———————————————————————————
4. Add Connection Location Digit from Table 4 —————————————————————————
5. Add Capillary Type Digit from Table 5 (enter “X” if none required) ———————————————————
6. Add Capillary Length Digit from Table 6 (enter “00” if none required) —————————————————————
7. Add Range Code Digits from Table 7 —————————————————————————————————————
8. Add Optional Feature Code Digit from Table 8 ————————————————————————————————————
CONNECTION LOCATION AVAILABILITY
CODE ALL SS ADJUSTABLE ANGLE REMOTE MOUNT
C = Center Back
L = Lower
R = Rear
TABLE 4
HOW TO ORDER
CODE CAPILLARY TYPE
S Spring Armor
I Interlock Armor*
X None
TABLE 5
CODE FAHRENHEIT
FR –320/100
FS –120/120
FC –40/180
FF 0/120
FI 0/300
FL 20/240
FN 50/550
FO 50/750
FQ 400/1200
TABLE 7 – STANDARD RANGES
TABLE 6
FEATURES OPTION CODE
Plastic Lens PD
Shatterproof Glass SG
Movable Red Set Hand SH
Markings on Dial DM
Paper Tag Attached to Instrument NN
Stainless Steel Tag Attached by Wire NH
CODE
LENGTH OF CAPILLARY TUBING
LENGTHS UP TO 100´
00 None
02
05
10 10´
*Required for lengths greater than 40 ft.
TABLE 8 – OPTIONS
CODE DUAL SCALE
DB –40/180°F & –40/80°C
DC –20/120°F & –80/50°C
DD 0/120°F & –15/50°C
DF 0/300°F & –10/150°C
DH 20/240°F & 0/110°C
DI 50/550°F & 10/290°C
DP 50/750°F & 0/400°C
DQ 400/1200°F & 200/650°C
29
Gas Actuated Thermometers –
Thermowells
“K” SERIES THERMOWELLS
(Fits
3
8˝ O.D. Bulb with
1
2˝ NPSM Swivel Nut)
0.A.
PART NUMBERS – 3/4 NPT**
LENGTH U DIM. BRASS 304 SS 316 SS
4
1
4 2
1
2 D1E5F2 D6E5F2 D4E5F2
6
3
4 5 D1M5F2 D6M5F2 D4M5F2
WITHOUT LAGGING EXTENSION
PART NUMBERS – 3/4 NPT
A U BRASS 304 SS 316 SS
4 2
1
2 S3B4K S3G4K S3J4K
6 4
1
2 S3B6K S3G6K S3J6K
WITHOUT LAGGING EXTENSION
“5F” SERIES THERMOWELL
(Fits
5
8˝ O.D. Bulb with 1-20 NEF-2B Swivel Nut)
30
Gas Actuated Thermometers –
Conversion Table
710 to 1300
C F
377 710 1310
382 720 1328
388 730 1346
393 740 1364
399 750 1382
404 760 1400
410 770 1418
416 780 1436
421 790 1454
427 800 1472
432 810 1490
438 820 1508
443 830 1526
449 840 1544
454 850 1562
460 860 1580
466 870 1598
471 880 1616
477 490 1634
482 900 1652
488 910 1670
493 920 1688
499 930 1706
504 940 1724
510 950 1742
516 960 1760
521 970 1778
527 980 1796
532 990 1814
538 1000 1832
543 1010 1850
549 1020 1868
554 1030 1886
560 1040 1904
566 1050 1922
571 1060 1940
577 1070 1958
582 1080 1976
588 1090 1994
593 1100 2012
599 1110 2030
604 1120 2048
610 1130 2066
616 1140 2084
621 1150 2102
627 1160 2120
632 1170 2138
638 1180 2156
643 1190 2174
649 1200 2192
654 1210 2210
660 1220 2228
666 1230 2246
671 1240 2264
677 1250 2282
682 1260 2300
688 1270 2318
693 1280 2336
699 1290 2354
704 1300 2372
120 to 700
C F
48.9 120 248
54.4 130 266
60.0 140 284
65.6 150 302
71.1 160 320
76.7 170 338
82.2 180 356
87.8 190 374
93.3 200 392
98.9 210 410
100 212 413.6
104 220 428
110 230 446
116 240 464
121 250 482
127 260 500
132 270 518
138 280 536
143 290 554
149 300 572
154 310 590
160 320 608
166 330 626
171 340 644
177 350 662
182 360 680
188 370 698
193 380 716
199 390 734
204 400 752
210 410 770
216 420 788
221 430 806
227 440 824
232 450 842
238 460 860
243 470 878
249 480 896
254 490 914
260 500 932
266 510 950
271 520 968
277 530 986
282 540 1004
288 550 1022
293 560 1040
299 570 1058
304 580 1076
310 590 1094
316 600 1112
321 610 1130
327 620 1148
332 630 1166
338 640 1184
343 650 1202
349 660 1220
354 670 1238
360 680 1256
366 690 1274
371 700 1292
51 to 110
C F
10.6 51 123.8
11.1 52 125.6
11.7 53 127.4
12.2 54 129.2
12.8 55 131.0
13.3 56 132.8
13.9 57 134.6
14.4 58 136.4
15.0 59 138.2
15.6 60 140.0
16.1 61 141.8
16.7 62 143.6
17.2 63 145.4
17.8 64 147.2
18.3 65 149.0
18.9 66 150.8
19.4 67 152.6
20.0 68 154.4
20.6 69 156.2
21.1 70 158.0
21.7 71 159.8
22.2 72 161.6
22.8 73 163.4
23.3 74 165.2
23.9 75 167.0
24.4 76 168.8
25.0 77 170.6
25.6 78 172.4
26.1 79 174.2
26.7 80 176.0
27.2 81 177.8
27.8 82 179.6
28.3 83 181.4
28.9 84 183.2
29.4 85 185.0
30.0 86 186.8
30.6 87 188.6
31.1 88 190.4
31.7 89 192.2
32.2 90 194.0
32.8 91 195.8
33.3 92 197.6
33.9 93 199.4
34.4 94 201.2
35.0 95 203.0
35.6 96 204.8
36.1 97 206.6
36.7 98 208.4
37.2 99 210.2
37.8 100 212.0
38.3 101 213.8
38.9 102 215.6
39.4 103 217.4
40.0 104 219.2
40.6 105 221.0
41.1 106 222.8
41.7 107 224.6
42.2 108 226.4
42.8 109 228.2
43.3 110 230.0
–9 to +50
C F
–22.8 –9 15.8
–22.2 –8 17.6
–21.7 –7 19.4
–21.1 –6 21.2
–20.6 –5 23.0
–20.0 –4 24.8
–19.4 –3 26.6
–18.9 –2 28.4
–18.3 –1 30.2
–17.8 0 32.0
–17.2 1 33.8
–16.7 2 35.6
–16.1 3 37.4
–15.6 4 39.2
–15.0 5 41.0
–14.4 6 42.8
–13.9 7 44.6
–13.3 8 46.4
–12.8 9 48.2
–12.2 10 50.0
–11.7 11 51.8
–11.1 12 53.6
–10.6 13 55.4
–10.0 14 57.2
–9.44 15 59.0
–8.89 16 60.8
–8.33 17 62.6
–7.78 18 64.4
–7.22 19 66.2
–6.67 20 68.0
–6.11 21 69.8
–5.56 22 71.6
–5.00 23 73.4
–4.44 24 75.2
–3.89 25 77.0
–3.33 26 78.8
–2.78 27 80.6
–2.22 28 82.4
–1.67 29 84.2
–1.11 30 86.0
–0.56 31 87.8
. 0 32 89.6
0.56 33 91.4
1.11 34 93.2
1.67 35 95.0
2.22 36 96.8
2.78 37 98.6
3.33 38 100.4
3.89 39 102.2
4.44 40 104.0
5.00 41 105.8
5.56 42 107.6
6.11 43 109.4
6.67 44 111.2
7.22 45 113.0
7.78 46 114.8
8.33 47 116.6
8.89 48 118.4
9.44 49 120.2
10.0 50 122.0
–459.4 to –10
C F
–273 –459.4
–268 –450
–262 –440
–257 –430
–251 –420
–246 –410
–240 –400
–234 –390
–229 –380
–223 –370
–218 –360
–212 –350
–207 –340
–201 –330
–196 –320
–190 –310
–184 –300
–179 –290
–173 –280
–169 –273 –459.4
–168 –270 –454
–162 –260 –436
–157 –250 –418
–151 –240 –400
–146 –230 –382
–140 –220 –364
–134 –210 –346
–129 –200 –328
–123 –190 –310
–118 –180 –292
–112 –170 –274
–107 –160 –256
–101 –150 –238
–95.6 –140 –220
–90.0 –130 –202
–84.4 –120 –184
–78.9 –110 –166
–73.3 –100 –148
–67.8 –90 –130
–62.2 –80 –112
–56.7 –70 –94.0
–51.1 –60 –76.0
–45.6 –50 –58.0
–40.0 –40 –40.0
–38.9 –38 –36.4
–37.8 –36 –32.8
–36.7 –34 –29.2
–35.6 –32 –25.6
–34.4 –30 –22.0
–33.3 –28 –18.4
–32.2 –26 –14.8
–31.1 –24 –11.2
–30.0 –22 –7.6
–28.9 –20 –4.0
–27.8 –18 –0.4
–26.7 –16 3.2
–25.6 –14 6.8
–24.4 –12 10.4
–23.3 –10 14.0
INTERPOLATION FACTORS
NOTE: The numbers in the center of each column
refer to the temperature either in degrees Celsius or
Fahrenheit which it is desired to convert into the
other scale. If converting from Fahrenheit degrees to
Celsius degrees the equivalent temperature will be
found in the left column, while if converting from
degrees Celsius to degrees Fahrenheit the answer
will be found in the column on the right.
C F
0.56 1 1.8
1.11 2 3.6
1.67 3 5.4
2.22 4 7.2
2.78 5 9.0
3.33 6 10.8
C F
3.89 7 12.6
4.44 8 14.4
5.00 9 16.2
5.56 10 18.0
31
32
Weksler Instruments
250 E. Main Street, Stratford, CT 06614
Tel: 203-378-8281 • Fax: 203-385-0408
www.ashcroft.com
All specifications are subject to change without notice. All sales subject to standard terms and conditions.
©Ashcroft Inc., 6/05 Rev. 09/10, 07/13, 06/16, 10/16